High-Efficiency Modulating Gas Furnace Retrofit in 1940s Historic Home
Symptom: A 28-year-old natural draft 80% furnace was short cycling, emitting burning odor, and struggling to keep back additions warm.
Finding: Cracked secondary heat exchanger cell with severe rollout trace and inadequate masonry chimney liner draft.
Resolution: Installed a 97% AFUE modulating gas furnace with ECM variable-speed blower, direct-vented through two-pipe PVC sidewall, rebuilt custom sheet metal plenum, and qualified homeowner for $400 Dominion Energy ThermWise rebate.